Multi Parameter Patient Monitor

  • Origin: Korea
  • Warranty: 01 Year.
  • Quality Standard: CE/FDA/ISO certificate Approval.
Category:

Description

Feature:

  • Standard Parameter : ECG, NIBP, SpO2, Temp, Resp.
  • Fully portability with steam line handle
  • High brightness 12.1” TFT color LCD
  • Big figure display
  • ECG waveform of 7-lead display in one screen
  • Compatible and self-identify 3/5-lead ECG cable
  • NIBP dual over pressure protection
  • Isolated floating, anti-defibrillation protected and
  •   anti-high frequency interference
  • 72 hours review trend
  • 480 hours review trend with external memory
  • Optional parameters & Configuration :
    2-IBP, EtCO2, 2-TEMP, Recorder, 12-lead ECG,
    Central Monitoring network S/W, Wireless Network,
    VGA output, Touch LCD
  • Built-in rechargeable battery
  • Dimension (mm) : 310(L) x 140 (W) x 263 (H)
  • Weight : 3.8 Kg

Technical Specifications

Classfication
Anti-electrochock type Class lequipment and internal powered equipment
EMC type Class A
Anti-electroshock degree ECG(RESP), SPO2, NIBP, IBP, TEMP, CO2, CF

 

Specifications  
Size Monitor 310 X 140 X 263 mm
Weight Monitor 3.8kg
Temperature Working 5 ~ 40℃
Transport / Storage -40 ~ +55℃
Humidity Working 30% ~ 75%
Transport / Storage ≤ 95% (no coagulate)
Altitude Working 700hPa ~ 1060hPa
Transport / Storage -500hPa ~ 1060hPa
Power Supply 100 ~ 240 VAC, 50/60Hz, Pmax = 150VA, FUSE T1.6A
Display Device 12.1 in. color TFT, 3 LED / 800 X 600 dots
Touch LCD(Option) viewing angle ( up : 70º, down : 70º, Left : 50º, Right : 60º and the best angle is 60º)
Messages – 8 Wave form Maximum

– 1 Power LED (Green)

– 3 Soung Mode corresponding Alarm Mode

– 1 Alarm LED (Yellow / Red)

– 1 Battery Charge LED (Yellow)

Signal Interface ECG Output BNC
Amplitude 1 mV
Accuracy < 5%
Impedance 50Ω
Signal Delay < 20ms
Battery – Rechargeble 3.7 A / Hr 7.4 V Li battery

– Operating time under the normal use and full charge greater than 120 min.

– Operating time after the first alarm of low battery will be about 5 min.

Recall Trend Recall – Short : 1hrs, 1 second Resolution

– Long : 72hrs, 1 min Resolution

Alarm Event Recall  71 alarm events of all parameters and 8/16/32 seconds of corresponding waveform.
NIBP Measurement

Recall

 At least 400 NIBP measurement data
 SD card  – 72 hrs ECG waveform  – 480 hrs TREND review
 ECG Lead mode 5 Leads (R, L, F, N, C or RA, LA, LL, RL, V)
Lead selection Ⅰ, Ⅱ, Ⅲ, avR, avL, avF, V
Waveform 2CH
Lead mode 3 Leads (R, L, F or RA, LA, LL)
Lead selection Ⅰ, Ⅱ, Ⅲ
Waveform 1ch
Gain x 2.5mm / mV, x5.0mm/mV, x10mm/mV, x20mm/mV
HR – Measuring Range : 15 ~ 300 bpm

– Alarm Range(PED/NEO) : 15~350bpm

– Resolution : 1bpm

– Alarm Rangle(ADU) : 15~300bpm

– Accuracy : ±1% or ±1bpm, which great

– Sensitivity : >200uV P-P

Differental input

Impedance

>5MΩ
CMRR – Monitor : ≥100dB

– Operation : ≥100dB

– Diagnosis : ≥60dB

Electode offset

potential

±300mV
Leakage Current <10uA
Baseline Recovery <5s After Defi
ECG Signal Range ±8mV(Vp-p)
Bandwidth – Surgery : 1 ~ 20Hz (+0.4dB, -3dB)

– Monitor : 0.5Hz ~ 40Hz (+0.4dB, -3dB)

– Diagnostic : 0.05Hz~75Hz (+0.4dB, -3dB), 76Hz~150Hz(+0.4dB, -4.5dB)

Calibration Signal 1mV(Vp-p), ±5% Accuracy
ST Segment

Monitoring Range

Measure Range : -0.6 ~ +0.8mV
Alarm Range : -2.0 ~ + 2.0mV
ARR Detecting Type : ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2, PVC,

TACHY, BRADY, MISSED BEATS, PNP, PNC

Alarm : Available
Review : Available
RESPARATION Method Impedance between R-F(RA-LL)
Differential Input

Impedance

>2.5MΩ
Measuring

Impedance Range

0.3 ~ 5.0Ω
Base line Impedance

Range

0.1 ~ 2.5KΩ
Bandwidth 0.3 ~ 2.5Hz
Resp. Rate – Measuring Range : 0 ~ 120rpm

– Alarm Range(PED/NEO) : 0 ~ 150 rpm

– Accuracy : ±2rpm

– Alarm Page(ADU) : 0 ~ 120rpm

– Resolution : 1rpm

Apnea Alarm 10 ~ 40S
NIEP Method Oscillometric  
Mode Manual, Auto, STAT
Measuring

Interval in AUTO

Mode

1, 2, 3, 4, 5, 10, 15, 30, 60, 90, 120, 180, 240, 480, 960 min
Measuring

period in STAT

Mode

5min
Alarm Type SYS, DIA, MEAN
Measuring and alarm Range  
Adult mode – SYS : 40 ~ 270mmHg

– DIA : 10 ~ 215mmHg

– MEAN : 20 ~ 235mmHg

Pediatric mode – SYS : 40 ~ 200mmHg

– DIA : 10 ~ 150mmHg

– MEAN : 20 ~ 165mmHg

Neonatal mode – SYS : 40 ~ 135mmHg

– DIA : 10 ~ 100mmHg

– MEAN : 20 ~ 110mmHg

Resolution Pressure : 1mmHg
Accuracy – Pressure(Maximum Mean error) : ±5mmHg

– Pressure(Maximum Standard deviation) : ±8mmHg

Overpressure

protection

– Adult mode : 297±3mmHg

– Pediatric mode : 240±3mmHg

– Neonatal mode : 147±3mmHg

SpO2 Measuring

Range

0 ~ 100%
Alarm Range 0 ~ 100%
Resolution 1%
Accuracy – 70 ~ 100% ±2%

– 0 ~ 69% unspecified

Actualization interval about 1sec
Alarm Delay 10sec
Pulse Rate – Measuring and Alarm Range : 0 ~ 250bpm

– Resolution : 1bpm

– Accuracy : ±2bpm

TEMPERATURE Channel 2
Measuring and

Alarm Range

0 ~ 50℃
Resolution 0.1℃
Accuracy ±0.2℃
Actualization

interval

about 1sec
Average Time

Constant

<10sec
IBP (Option) Channel 2
Label ART, PA, CVP, RAP, LAP, ICP, P1, P2
Measuring

range

-10 ~ +300mmHg
Alarm range -50 ~ +350mmHg
Press Sensor – Sensitivity : 5uV/V/mmHg

– Impedance : 300 ~ 3000Ω

Resolution 1mmHg
Accracy ±2% or 1mmHg which great
Actualization

Interval

about 1sec
CO2

(Option)

Method Infra-red Absorption Technique
Measuring

mode

Mainstream and Sidestream
Side-stream

mode sampling

gas flow rate

50ml/Min. ± 10ml/Min.
Measuring range CO2 : 0 ~ 150 mmHg

INSCO2 : 0 ~ 150 mmHg

AwRR : 2 ~ 150 rpm

Resolution CO2 : 0.1mmHg (0 ~ 69mmHg), 0.25mmHg (70 ~ 150mmHg)

INSCO2 : 0.1mmHg (0 ~ 69mmHg), 0.25mmHg (70 ~ 150mmHg)

Accuracy – CO2 : ±2mmHg, 0 ~ 40mmHg

±5% of reading, 41 ~ 70mmHg

±8% of reading, 71 ~ 100mmHg

±10% of reading, 101 ~ 150mmHg

– AwRR : ±1rpm

Pace maker (Option) Availalbe
Initialization

Time

– Mainstrea : Capnogram displayed in less than 15sec at an ambient Temp. of 25 ℃,

full sepcification within 2 min

– Sidestrea : Capnogram displayed in less than 20sec at an ambient Temp. of 25℃,

full sepcification within 2 min

– Mainstream Rise Time : Less then 60ms-Adult Reusable or Single-Patient-Use

Airway Adapter Less then 60ms-Infant Reusable or Single-Patient-Use Airway Adapter

Acutualization interval about 1sec
Sidestream

Delay Time<</table>

 