I. Syringe Pump

  • Origin: China
  • Warranty: 01 Year.
  • Quality Standard: CE/FDA/ISO certificate Approval.
Category:

Description

  • Functions
  • Function (M200): Rate Mode , Time Mode, Weight Mode, Intermittent Administration Mode, TIVA Induction Mode
  • Function (M200A): Rate Mode
  • Range of Rate
  1. 5ml syringe: 1ml/h~100ml/h (step size: 0.1ml/h; error: ±3%);
  2. 10ml syringe: 1ml/h~300ml/h (step size: 0.1ml/h; error: ±3%);
  3. 20ml syringe: 1ml/h~400ml/h (step size: 0.1ml/h; error: ±3%);
  4. 30ml syringe: 1ml/h~600ml/h (step size: 0.1ml/h; error: ±3%);
  5. 50ml syringe: 1ml/h~1200ml/h (step size: 0.1ml/h; error: ±3%). Range of preset total volume: 0.1~9999.9ml
  • Range of KVO Rate
  1. KVO rate of injection pump M200: 1ml/h~5.0ml/h.
  2. KVO rate of injection pump M200A: 5ml/h.
  • Range of total volume
  1. a) Range of Total Volume Infused:0.1~9999.9ml,Display Resolution: 1ml. Performance of the base (for injection pump M200 only)
  • Time mode
  • 1.Preset Dose: 0.1ml~9999.9ml. 2.Preset time range: 1min~5999min.
  • Weight mode
  1. Weight range:1kg~250kg.
  2. Drug concentration range: 001μg/ml~999.999μg/ml.
  • Intermittent Administration Mode
  1. Injection rate range:
    1. 5ml syringe: 1ml/h~100ml/h (step size: 0.1ml/h);
    2. 10ml syringe: 1ml/h~300ml/h (step size: 0.1ml/h);
    3. 20ml syringe: 1ml/h~400ml/h (step size: 0.1ml/h);
    4. 30ml syringe: 1ml/h~600ml/h (step size: 0.1ml/h);
    5. 50ml syringe: 1ml/h~1200ml/h (step size: 0.1ml/h). 2.Injection Volume range:0.1ml~50ml.
  • 3.Time Interval:1min~120min.
  • TIVA mode
  • 1.Weight:1kg~250kg. 2.Drug Concentration:0.001μg/ml~999.999μg/ml. 3.Induce Dose:0.001ug/kg~999.999ug/kg. 4. Induce Time:1s~1200s.
  • Block pressure alarm limit
  1. Level mode
  • Three block pressure alarm levels: Low: 300mmHg; Medium: 600mmHg; High: 900mmHg; Error: ±100mmHg.
  1. Value mode (for injection pump M200 only); block pressure alarm limit: 50mmHg~1000mmHg. Alarms: alarm for residual indicator, alarm for infusion completion, alarm for tube block,
  • alarm for Unclamped barrel, alarm for improperly installed plunger, alarm for speed out of range, alarm for output volume equivalent to limited amount, alarm for power cord falloff,
  • alarm for battery used Up, alarm for system error, alarm for neglected operation
  • Power supply
  1. AC power supply: 100V-240V~,50/60Hz
  2. M200A built-in battery: 1V rechargeable lithium-ion battery; the fully charged battery allows over 8.0h working time at the rate of 5ml/h.
  • M200 base built-in battery: DC11.1V rechargeable lithium-ion battery; the fully charged battery allows the base to work for over 8h .
  • Operating environment conditions:
  1. Range of ambient temperature: 5℃~40℃
  2. Range of relative humidity: 20%~90%
  3. Range of atmospheric pressure: 700hPa~1060hPa
  4. Power supply: 100V-240V~,50/60Hz
  5. Built-in battery: DC 1V
  6. The syringe pump should work in an environment without strong impact,
  • vibration or corrosive gas and where water and other fluids cannot flow into the device.
  • Transportation and storage conditions:
  1. Range of ambient temperature:﹣40℃~+60℃
  2. Range of relative humidity: ≤90%
  • Range of atmospheric pressure: 700hPa~1060hPa